T-90A/S Object 188A1(S) with KE2K

 A prototype version of T-90A/S equipped with the KE2K power/air conditioning unit, designed by SPA "Electromashina". KE2K is mounted in the rear of the turret, replacing the spare parts container. This unit was designed to provide the crew with stable temperatures in extreme climates, help cool the gunners thermal imaging sight and act as an APU to provide additional power. 


The power unit-air conditioner, developed and manufactured by SPA "Elektromashina", is intended for;

    - cooling of electronic devices, incl. thermal imager "ESSA"
    - preservation of the resource of the main engine
    - power supply of electrical equipment of the tank (weapons, radio station, etc.) for when the main engine is not used
    - automatic charging of the main storage batteries
    - increasing the efficiency of the crew



Output voltage: 27.5 V

Power produced: 
    - in air conditioner mode - 0.5-4 kW
    - in power unit mode - 6.5 kW

Number of cooling units - 4

Time of continuous operation without refuelling - 8 hours.

Dimensions of the main cooling unit


KE2K was mounted on a T-90S tank for testing in January-February of 2010. The T-90S with KE2K did not get past testing phases and was never put into production. 

Taken from: Book "UKBTM 75 year anniversary of the Tagil tank building school" 